Zuhause> Produkt-Liste> Stromsensor> Motorrad-elektronischer Kontrollstromsensor DXE-DM18
Motorrad-elektronischer Kontrollstromsensor DXE-DM18
Motorrad-elektronischer Kontrollstromsensor DXE-DM18
Motorrad-elektronischer Kontrollstromsensor DXE-DM18

Motorrad-elektronischer Kontrollstromsensor DXE-DM18

$1≥100Piece/Pieces

Zahlungsart:T/T
Incoterm:FOB,CFR,CIF,EXW,FAS,FCA
Minimum der Bestellmenge:100 Piece/Pieces
Transport:Ocean,Land,Air,Express
Hafen:SHANGHAI,NINGBO,GUANGZHOU
Produkteigenschaften

ModellDXE-DM18

MarkeDexie, OEM -Service ist verfügbar

HerkunftsortChina

Accuracy1%

Verpackung & Lieferung
Verkaufseinheiten : Piece/Pieces
Pakettyp : Kartons / Palette
Herunterladen :

The file is encrypted. Please fill in the following information to continue accessing it

Produktbeschreibung

Stromsensor DXE-DM18



TYP

DXE-DM18-200A

DXE-DM18-300A

DXE-DM18-400A

DXE-DM18-500A

DXE-DM18-600A

DXE-DM18-700A

DXE-DM18-800A

DXE-DM18-900A

DXE-DM18-1000A

DXE-DM18-1100A

DXE-DM18-1200A


Merkmale

● Hervorragende Genauigkeit- Genauigkeitsfehler <1%

● Sehr gute Linearität- Linearitätsfehler <0,5%

● Mehrere Modelle- 200a, 300a, 400a, 500A, 600A, 700A, 800A, 900A, 1000A, 1100A, 1200

● breite Frequenzbandbreite- > 120 kHz

● hohe Druckfestigkeit- > 2KV

● Sensorbetriebstemperaturbereich - -40 ℃ bis +125 ℃


Anwendungsbereich _

● Batterieverwaltungssystem (Elektrofahrzeuge) (BMS)

● Batteriesystemverteilungsbox (BDU)

● Hochspannungsverteilungskasten (PDU) für Elektrofahrzeuge

● Energiemanagement von industriellen Lithiumbatterien


Elektrische Daten Versorgungsspannung = VCC = 5V

Grenzparameter (Hinweis: Überschreiten Sie den Maximalwert nicht, um Schäden zu verhindern. Längerer Betrieb mit dem Höchstwert kann die Zuverlässigkeit des Geräts beeinflussen)

Parameter

Symbol

Specifications

Unit

Condition

Minimum operating voltage

Vcc

4.8

V


Maximum working voltage

Vcc

6

V


Output voltage

Vout

5

V


Storage temperature

Ts

-45-135


Junction temperature

Tj

165


ESD

HBM

8000

V

 HBM model per Mil-Std-883, Method 3015

ESD

MM

400

V

  MM model per JEDEC EIA/JESD22-A115

Latch-up test per JEDEC 78


200

mA


Dissipation power

Pd

550

mW


Dielectric Strength

VD

2000

V

50Hz,1min


Standardparameter (sofern nicht anders angegeben: TA = 25 , CP = 0,1UF, VCC = 5V)

Parameter

Symbol

Specifications

Unit

Condition

Minimum

Standard

Maximum

Supply Voltage

Vcc

4.8

5

5.2

V


Working current @Ip=0A

Ic


10

15

Ma


Static output voltage

Vout

2.48

2.5

2.52

V


Output High Voltage

VOH

4.8

-

-

V


Output Low Voltage

VOL

-

-

0.2

V


Output resistance

ROUT

-

-

100

Ω


Power on response time

TPO

-

0.1

0.2

ms


Output response time

tRESPONSE

-

3.7

-

us


Bandwidth

BW

0

-

120

KHz


Ambient Temperature

TA

-40

-

125



Genauigkeitsparameter (sofern nicht anders angegeben: TA = 25 , CP = 0,1UF, VCC = 5V)

Sicherheitsmerkmale

Parameter

Symbol

Specifications

Unit

Condition

Minimum

Standard

Maximum

Sensitivity

Sense

9.90

10.00

10.10

mV/A

DXE-DM18-200A

6.60

6.67

6.73

mV/A

DXE-DM18-300A

4.95

5.00

5.05

mV/A

DXE-DM18-400A

3.96

4.00

4.04

mV/A

DXE-DM18-500A

3.30

3.33

3.37

mV/A

DXE-DM18-600A

2.83

2.86

2.89

mV/A

DXE-DM18-700A

2.48

2.50

2.53

mV/A

DXE-DM18-800A

2.20

2.22

2.24

mV/A

DXE-DM18-900A

1.98

2.00

2.02

mV/A

DXE-DM18-1000A

1.80

1.82

1.84

mV/A

DXE-DM18-1100A

1.65

1.67

1.68

mV/A

DXE-DM18-1200A

Linearity

Lin

-0.50

-

0.50

%


Temperature characteristics

VOUT (T)

-1.50

-

1.50

%


Sense(T)

2.50

-

2.50

%


Measuring current

IP

-200.00

-

200.00

A

DXE-DM18-200A

-300.00

-

300.00

A

DXE-DM18-300A

-400.00

-

400.00

A

DXE-DM18-400A

-500.00

-

500.00

A

DXE-DM18-500A

-600.00

-

600.00

A

DXE-DM18-600A

-700.00

-

700.00

A

DXE-DM18-700A

-800.00

-

800.00

A

DXE-DM18-800A

-900.00

-

900.00

A

DXE-DM18-900A

-1000.00

-

1000.00

A

  DXE-DM18-1000A

-1100.00

-

1100.00

A

  DXE-DM18-1100A

-1200.00

-

1200.00

A

  DXE-DM18-1200A

Measuring range

IP

-220.00

-

220.00

A

DXE-DM18-200A

-330.00

-

330.00

A

DXE-DM18-300A

-440.00

-

440.00

A

DXE-DM18-400A

-550.00

-

550.00

A

DXE-DM18-500A

-660.00

-

660.00

A

DXE-DM18-600A

-770.00

-

770.00

A

DXE-DM18-700A

-880.00

-

880.00

A

DXE-DM18-800A

-990.00

-

990.00

A

DXE-DM18-900A

-1100.00

-

1100.00

A

DXE-DM18-1000A

-1210.00

-

1210.00

A

DXE-DM18-1100A

-1320.00

-

1320.00

A

DXE-DM18-1200A

Output noise

VP-P

-

20.00

-

mV

Cp=100nF,CL=1.5nF

VRMS

-

2.30

-

mV

CP=100nF,CL=1.5nF


Arbeitsprinzip

Bei Strom (IP = 0a) beträgt die Spannung des Ausgangsstifts die Hälfte der Stromversorgungsspannung. Wenn der Strom durch das durch das Durchschnittsloch in der Mitte des Sensors aus der Vorwärtsrichtung durchläuft, nimmt die Ausgangsspannung entsprechend zu. Im Gegenteil, wenn der Strom durch das mittlere Loch des Sensors in die entgegengesetzte Richtung fließt, nimmt die Ausgangsspannung entsprechend ab und die Amplitude des Anstiegs oder Abnahmes ist symmetrisch.


Zuhause> Produkt-Liste> Stromsensor> Motorrad-elektronischer Kontrollstromsensor DXE-DM18
  • Mobiltelefon:

    +8618668863822

  • E-Mail-Adresse:

    cb_dennis@163.com

  • Firmenadresse:

    Shanghai, Shanghai China

  • Follow us:

Newsletter

Sign up for industry alerts, our latest news. thoughts, and insights from Shanghai Zhilong Electronic Technology Co.,Ltd.

Copyright ©2024 Shanghai Zhilong Electronic Technology Co.,LtdAlle Rechte vorbehalten
Anfrage versenden
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

senden