Modell: DXE-DM14
Marke: Dexie, OEM -Service ist verfügbar
Herkunftsort: China
Accuracy: 1%
Verkaufseinheiten | : | Piece/Pieces |
Pakettyp | : | Kartons / Palette |
Herunterladen | : |
The file is encrypted. Please fill in the following information to continue accessing it
Stromsensor DXE-DM14
TYP
DXE-DM14-100A
DXE-DM14-200A
DXE-DM14-300A
DXE-DM14-400A
DXE-DM14-500A
DXE-DM14-600A
DXE-DM14-700A
DXE-DM14-800A
Merkmale
● Hervorragende Genauigkeit- Genauigkeitsfehler <1%
● Sehr gute Linearität- Linearitätsfehler <0,5%
● Mehrere Modelle- 100a, 200a, 300A, 400A, 500A, 600A, 700A, 800A
● breite Frequenzbandbreite- > 120 kHz
● hohe Druckfestigkeit- > 2KV
● Sensorbetriebstemperaturbereich - -40 ℃ bis +125 ℃
Anwendungsbereich _
● Batterieverwaltungssystem (Elektrofahrzeuge) (BMS)
● Batteriesystemverteilungsbox (BDU)
● Hochspannungsverteilungskasten (PDU) für Elektrofahrzeuge
● Energiemanagement von industriellen Lithiumbatterien
Elektrische Daten ( Versorgungsspannung = VCC = 5V )
Grenzparameter (Hinweis: Überschreiten Sie den Maximalwert nicht, um Schäden zu verhindern. Längerer Betrieb mit dem Höchstwert kann die Zuverlässigkeit des Geräts beeinflussen)
Parameter |
Symbol |
Specifications |
Unit |
Condition |
Minimum operating voltage |
Vcc |
4.8 |
V |
|
Maximum working voltage |
Vcc |
6 |
V |
|
Output voltage |
Vout |
5 |
V |
|
Storage temperature |
Ts |
-45-135 |
℃ |
|
Junction temperature |
Tj |
165 |
℃ |
|
ESD |
HBM |
8000 |
V |
HBM model per Mil-Std-883, Method 3015 |
ESD |
MM |
400 |
V |
MM model per JEDEC EIA/JESD22-A115 |
Latch-up test per JEDEC 78 |
|
200 |
mA |
|
Dissipation power |
Pd |
550 |
mW |
|
Dielectric Strength |
VD |
2000 |
V |
50Hz,1min |
Standardparameter (sofern nicht anders angegeben: TA = 25 ℃ , CP = 0,1UF, VCC = 5V)
Parameter |
Symbol |
Specifications |
Unit |
Condition |
||
Minimum |
Standard |
Maximum |
||||
Supply Voltage |
Vcc |
4.8 |
5 |
5.2 |
V |
|
Working current @Ip=0A |
Ic |
|
10 |
15 |
mA |
|
Static output voltage |
Vout |
2.48 |
2.5 |
2.52 |
V |
|
Output High Voltage |
VOH |
4.8 |
- |
- |
V |
|
Output Low Voltage |
VOL |
- |
- |
0.2 |
V |
|
Output resistance |
ROUT |
- |
- |
100 |
Ω |
|
Power on response time |
TPO |
- |
0.1 |
0.2 |
ms |
|
Output response time |
tRESPONSE |
- |
3.7 |
- |
us |
|
Bandwidth |
BW |
0 |
- |
120 |
KHz |
|
Ambient Temperature |
TA |
-40 |
- |
125 |
℃ |
|
Genauigkeitsparameter (sofern nicht anders angegeben: TA = 25 ℃ , CP = 0,1UF, VCC = 5V)
Sicherheitsmerkmale
Parameter |
Symbol |
Specifications |
Unit |
Condition |
||
Minimum |
Standard |
Maximum |
||||
Sensitivity |
Sense |
19.80 |
20.00 |
20.20 |
mV/A |
DXE-DM12-100A |
9.90 |
10.00 |
10.10 |
mV/A |
DXE-DM12-200A |
||
6.60 |
6.67 |
6.74 |
mV/A |
DXE-DM12-300A |
||
4.95 |
5.00 |
5.05 |
mV/A |
DXE-DM12-400A |
||
3.96 |
4.00 |
4.04 |
mV/A |
DXE-DM12-500A |
||
3.30 |
3.33 |
3.37 |
mV/A |
DXE-DM12-600A |
||
2.83 |
2.86 |
2.89 |
mV/A |
DXE-DM12-700A |
||
2.48 |
2.50 |
2.53 |
mV/A |
DXE-DM12-800A |
||
Linearity |
Lin |
-0.50 |
- |
0.50 |
% |
|
Temperature characteristics |
VOUT (T) |
-1.50 |
- |
1.50 |
% |
|
Sense(T) |
2.50 |
- |
2.50 |
% |
|
|
Measuring current
|
IP |
-100.00 |
- |
100.00 |
A |
DXE-DM12-100A |
-200.00 |
- |
200.00 |
A |
DXE-DM12-200A |
||
-300.00 |
- |
300.00 |
A |
DXE-DM12-300A |
||
-400.00 |
- |
400.00 |
A |
DXE-DM12-400A |
||
-500.00 |
- |
500.00 |
A |
DXE-DM12-500A |
||
-600.00 |
- |
600.00 |
A |
DXE-DM12-600A |
||
-700.00 |
- |
700.00 |
A |
DXE-DM12-700A |
||
-800.00 |
- |
800.00 |
A |
DXE-DM12-800A |
||
Measuring range
|
IP |
-110.00 |
- |
110.00 |
A |
DXE-DM12-100A |
-220.00 |
- |
220.00 |
A |
DXE-DM12-200A |
||
-330.00 |
- |
330.00 |
A |
DXE-DM12-300A |
||
-440.00 |
- |
440.00 |
A |
DXE-DM12-400A |
||
-550.00 |
- |
550.00 |
A |
DXE-DM12-500A |
||
-660.00 |
- |
660.00 |
A |
DXE-DM12-600A |
||
-770.00 |
- |
770.00 |
A |
DXE-DM12-700A |
||
-880.00 |
- |
880.00 |
A |
DXE-DM12-800A |
||
Output noise |
VP-P |
- |
20.00 |
- |
mV |
Cp=100nF,CL=1.5nF |
VRMS |
- |
2.30 |
- |
mV |
CP=100nF,CL=1.5nF |
Mechanische Eigenschaften
Characteristic |
Rating |
Unit |
General tolerance |
± 0.5 |
mm |
Other tolerance execution |
GB/T 1804-2000-M |
|
Fixed Pin size |
Φ1*3 |
mm |
Pin size |
0.5*0.5*3 |
mm |
Recommended welding temperature |
265±5 |
℃ |
Weight |
12 |
g |
Shell material |
PA66 |
|
Pin material |
tinned brass |
|
Arbeitsprinzip
Bei Strom (IP = 0a) beträgt die Spannung des Ausgangsstifts die Hälfte der Stromversorgungsspannung. Wenn der Strom durch das durch das Durchschnittsloch in der Mitte des Sensors aus der Vorwärtsrichtung durchläuft, nimmt die Ausgangsspannung entsprechend zu. Im Gegenteil, wenn der Strom durch das mittlere Loch des Sensors in die entgegengesetzte Richtung fließt, nimmt die Ausgangsspannung entsprechend ab und die Amplitude des Anstiegs oder Abnahmes ist symmetrisch.